climateprediction.net home page
Task 12723556

Task 12723556

Name hadam3p_eu_w9mw_1967_1_006807840_2
Workunit 7011156
Created 25 Mar 2011, 18:52:58 UTC
Sent 25 Mar 2011, 19:21:17 UTC
Report deadline 7 Mar 2012, 0:41:17 UTC
Received 1 Apr 2011, 16:00:02 UTC
Server state Over
Outcome Didn't need
Client state Compute error
Exit status 0 (0x00000000)
Computer ID 1053444
Run time 12 hours 46 min 53 sec
CPU time 10 hours 48 min 23 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 2.07 GFLOPS
Application version UK Met Office HadAM3P-HadRM3P Europe v6.09
windows_intelx86
Stderr
<core_client_version>6.10.18</core_client_version>
<![CDATA[
<stderr_txt>
16:38:37 (5824): No heartbeat from core client for 30 sec - exiting
16:38:38 (5824): No heartbeat from core client for 30 sec - exiting
16:38:39 (5824): No heartbeat from core client for 30 sec - exiting
16:38:40 (5824): No heartbeat from core client for 30 sec - exiting
16:38:41 (5824): No heartbeat from core client for 30 sec - exiting
16:38:42 (5824): No heartbeat from core client for 30 sec - exiting
16:38:43 (5824): No heartbeat from core client for 30 sec - exiting
16:38:44 (5824): No heartbeat from core client for 30 sec - exiting
16:38:45 (5824): No heartbeat from core client for 30 sec - exiting
16:38:46 (5824): No heartbeat from core client for 30 sec - exiting
16:38:47 (5824): No heartbeat from core client for 30 sec - exiting
16:38:48 (5824): No heartbeat from core client for 30 sec - exiting
16:38:49 (5824): No heartbeat from core client for 30 sec - exiting
CPDN Monitor - No 'heartbeat' from BOINC...
CPDN Monitor - Quit request from BOINC...
Regional Worker:: CPDN process is not running, exiting, bRetVal = 1, checkPID=2696, selfPID=2696, iMonCtr=2
18:29:09 (6852): No heartbeat from core client for 30 sec - exiting
CPDN Monitor - No 'heartbeat' from BOINC...
CPDN Monitor - Quit request from BOINC...
forrtl: The requested operation cannot be performed on a file with a user-mapped section open.
forrtl: severe (38): error during write, unit 6, file C:\ProgramData\BOINC\projects\climateprediction.net\hadam3p_eu_w9mw_1967_1_006807840\dataout\xaakm.out
Image              PC        Routine            Line        Source             
hadam3p_eu_um_6.0  0140A39A  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  013B2CD0  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  013B1E9A  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  01385DA1  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  01382CA5  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  0132E79E  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  0132F2DA  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  010A9BD2  Unknown               Unknown  Unknown
hadam3p_eu_um_6.0  013EE638  Unknown               Unknown  Unknown
kernel32.dll       7558D0E9  Unknown               Unknown  Unknown
ntdll.dll          76EC16C3  Unknown               Unknown  Unknown
ntdll.dll          76EC1696  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=7760, selfPID=6736, iMonCtr=1
Model crash detected, will try to restart...
Leaving CPDN_Main::Monitor...
Called boinc_finish

</stderr_txt>
<message>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_1.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_2.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_3.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_4.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_5.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_6.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_7.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_8.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_9.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_10.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_11.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_eu_w9mw_1967_1_006807840_2_12.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>

</message>
]]>
No trickles!


©2024 climateprediction.net