Task 12725872

Name hadam3p_pnw_z5nt_2000_1_006928257_1
Workunit 7131573
Created 26 Mar 2011, 11:22:36 UTC
Sent 26 Mar 2011, 13:31:58 UTC
Report deadline 7 Mar 2012, 18:51:58 UTC
Received 30 Mar 2011, 17:30:51 UTC
Server state Over
Outcome Didn't need
Client state Compute error
Exit status 0 (0x00000000)
Computer ID 1111197
Run time 10 sec
CPU time 1 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 3.20 GFLOPS
Application version UK Met Office HadAM3P-HadRM3P Pacific North West v6.09
windows_intelx86
Stderr
<core_client_version>6.10.58</core_client_version>
<![CDATA[
<stderr_txt>

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/xaakm.pipe_dummy                                                            2048    
Leaving CPDN_Main::Monitor...
Regional yearly means requires 12 input files got 0
Called boinc_finish

</stderr_txt>
<message>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_1.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_2.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_3.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_4.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_5.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_6.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_7.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_8.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_9.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_10.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_11.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_12.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>hadam3p_pnw_z5nt_2000_1_006928257_1_13.zip</file_name>
  <error_code>-161</error_code>
</file_xfer_error>