climateprediction.net home page
Task 12832269

Task 12832269

Name hadcm3n_p6mj_1900_40_007226171_0
Workunit 7424411
Created 26 Apr 2011, 15:36:46 UTC
Sent 27 Apr 2011, 8:00:04 UTC
Report deadline 27 Jul 2011, 15:27:15 UTC
Received 27 May 2011, 2:21:27 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1139331
Run time 16 days 11 hours 55 min 20 sec
CPU time 15 days 7 hours 24 min 7 sec
Validate state Invalid
Credit 11,197.44
Device peak FLOPS 3.27 GFLOPS
Application version UK Met Office Coupled Model Full Resolution Ocean v6.07
i686-apple-darwin
Stderr
<core_client_version>6.10.58</core_client_version>
<![CDATA[
<message>
process exited with code 22 (0x16, -234)
</message>
<stderr_txt>

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 63 - Return code = 1

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 64 - Return code = 1

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 65 - Return code = 1

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 66 - Return code = 1

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 67 - Return code = 1

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 68 - Return code = 1

BUFFIN: Read Failed: No such file or directory
BUFFIN: C I/O Error feof - Unit 69 - Return code = 1
Error: Input file: dataout/p6mjko.pjd6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjko.pjd6c10
Error: Input file: dataout/p6mjko.pid6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjko.pid6c10
Error: Input file: dataout/p6mjko.pfd6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjko.pfd6c10
Error: Input file: dataout/p6mjka.phd6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjka.phd6c10
Error: Input file: dataout/p6mjka.pgd6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjka.pgd6c10
Error: Input file: dataout/p6mjka.ped6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjka.ped6c10
Error: Input file: dataout/p6mjka.pdd6c10 is not a valid UM file.
Error converting file to netcdf: dataout/p6mjka.pdd6c10
OPEN:  File Creation Failed: No space left on device
OPEN:  Unable to Open File dataout/p6mjko.dad6c90 for Read/Write

Model crashed: DUMPCTL : Fail to open output dump - may already exist                                                                                                                                                                                                          tmp/pipe_dummy                                                                  2048    
forrtl: No space left on device
forrtl: severe (38): error during write, unit 6, file /Library/Application Support/BOINC Data/projects/climateprediction.net/hadcm3n_p6mj_1900_40_007226171/dataout/stdout_um.txt
Image              PC        Routine            Line        Source             
hadcm3n_um_6.07_i  0042E622  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  0042D0EB  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003EF4DD  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003A66F5  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003A5E57  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003E1E32  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003DF4CC  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003651C5  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  002DE95F  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  00389F90  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  000048E1  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  000027FB  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  00002729  Unknown               Unknown  Unknown
Unknown            00000003  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=60056, iMonCtr=1
Model crash detected, will try to restart...
forrtl: No space left on device
forrtl: severe (38): error during write, unit 6, file /Library/Application Support/BOINC Data/projects/climateprediction.net/hadcm3n_p6mj_1900_40_007226171/dataout/stdout_um.txt
Image              PC        Routine            Line        Source             
hadcm3n_um_6.07_i  0042E622  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  0042D0EB  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003EF4DD  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003A66F5  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003A5E57  Unknown               Unknown  Unknown
hadcm3n_um_6.07_i  003E1E32  Unknown  Sorry, too many model crashes! :-(
Called boinc_finish

</stderr_txt>
]]>
Latest Trickles Received
Time Sent (UTC) Host ID Result ID Result Name Timestep CPU Time (sec) Average (sec/TS)
26 May 2011 21:55:25 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 933,120 1,322,612 1.4174
26 May 2011 11:44:57 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 907,200 1,288,088 1.4199
26 May 2011 01:51:44 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 881,280 1,253,595 1.4225
25 May 2011 12:55:40 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 855,360 1,215,740 1.4213
24 May 2011 23:43:35 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 829,440 1,176,938 1.4190
24 May 2011 12:10:00 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 803,520 1,139,870 1.4186
24 May 2011 00:45:30 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 777,600 1,102,313 1.4176
23 May 2011 13:35:42 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 751,680 1,065,223 1.4171
23 May 2011 02:29:46 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 725,760 1,028,435 1.4170
22 May 2011 15:23:06 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 699,840 991,368 1.4166
22 May 2011 04:17:14 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 673,920 954,247 1.4160
21 May 2011 17:26:14 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 648,000 917,871 1.4165
21 May 2011 06:24:24 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 622,080 881,034 1.4163
20 May 2011 19:30:08 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 596,160 844,414 1.4164
20 May 2011 08:13:35 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 570,240 806,635 1.4146
19 May 2011 20:58:09 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 544,320 769,145 1.4130
19 May 2011 08:28:37 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 518,400 731,600 1.4113
18 May 2011 22:09:12 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 492,480 695,792 1.4128
18 May 2011 10:30:27 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 466,560 659,470 1.4135
17 May 2011 23:27:43 1139331 12832269 hadcm3n_p6mj_1900_40_007226171_0 440,640 622,974 1.4138


©2024 climateprediction.net