Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1335752
Run time 22 hours 33 min 10 sec
CPU time 22 hours 32 min 3 sec
Validate state Invalid
Credit 4,355.42
Device peak FLOPS 4.25 GFLOPS
Application version UK Met Office HadCM3 short v8.29
windows_intelx86
Peak working set size 165.63 MB
Peak swap size 194.91 MB
Peak disk usage 51.38 MB
Stderr
<core_client_version>7.6.22</core_client_version>
<![CDATA[
<message>
The device does not recognize the command.
 (0x16) - exit code 22 (0x16)
</message>
<stderr_txt>
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
Suspended CPDN Monitor - Suspend request from BOINC...
CPDN Monitor - Quit request from BOINC...

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  
Sorry, too many model crashes! :-(
12:44:20 (5520): called boinc_finish(22)