Name | hadam4_a01x_200610_6_848_011923244_3 |
Workunit | 11923244 |
Created | 18 Nov 2019, 9:01:00 UTC |
Sent | 1 Jan 2020, 2:23:26 UTC |
Report deadline | 13 Dec 2020, 7:43:26 UTC |
Received | 1 Jan 2020, 3:29:58 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1473650 |
Run time | 16 min 35 sec |
CPU time | 14 min 49 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 6.11 GFLOPS |
Application version | UK Met Office HadAM4 at N144 resolution v8.09 i686-pc-linux-gnu |
Peak working set size | 618.28 MB |
Peak swap size | 647.23 MB |
Peak disk usage | 5.78 MB |
Stderr | <core_client_version>7.9.3</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 18:41:10 (14478): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|