Name | hadam4_a2ea_210010_6_853_011943141_3 |
Workunit | 11943141 |
Created | 30 Dec 2019, 10:00:17 UTC |
Sent | 30 Dec 2019, 11:08:59 UTC |
Report deadline | 11 Dec 2020, 16:28:59 UTC |
Received | 31 Dec 2019, 21:02:52 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1484259 |
Run time | 13 min 40 sec |
CPU time | 12 min 33 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.67 GFLOPS |
Application version | UK Met Office HadAM4 at N144 resolution v8.09 i686-pc-linux-gnu |
Peak working set size | 618.36 MB |
Peak swap size | 647.00 MB |
Peak disk usage | 5.78 MB |
Stderr | <core_client_version>7.9.3</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 22:12:32 (19786): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|
©2024 cpdn.org