Name | hadam4_a0tp_209410_6_853_011941104_4 |
Workunit | 11941104 |
Created | 22 Jan 2020, 17:02:31 UTC |
Sent | 22 Jan 2020, 17:23:39 UTC |
Report deadline | 3 Jan 2021, 22:43:39 UTC |
Received | 22 Jan 2020, 18:50:42 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1496469 |
Run time | 7 min 6 sec |
CPU time | 6 min 30 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.43 GFLOPS |
Application version | UK Met Office HadAM4 at N144 resolution v8.09 i686-pc-linux-gnu |
Peak working set size | 618.44 MB |
Peak swap size | 647.00 MB |
Peak disk usage | 5.78 MB |
Stderr | <core_client_version>7.9.3</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 11:50:37 (2148): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|
©2024 climateprediction.net