Name | hadam4h_a1lq_209711_4_863_011986353_2 |
Workunit | 11986353 |
Created | 17 Feb 2020, 7:43:53 UTC |
Sent | 17 Feb 2020, 10:04:04 UTC |
Report deadline | 29 Jan 2021, 15:24:04 UTC |
Received | 18 Feb 2020, 14:16:31 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1496749 |
Run time | 1 days 0 hours 56 min 23 sec |
CPU time | 1 days 0 hours 51 min 11 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.49 GFLOPS |
Application version | UK Met Office HadAM4 at N216 resolution v8.52 i686-pc-linux-gnu |
Peak working set size | 1,364.39 MB |
Peak swap size | 1,385.94 MB |
Peak disk usage | 12.91 MB |
Stderr | <core_client_version>7.9.3</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Suspended CPDN Monitor - Suspend request from BOINC... Signal 15 received: Software termination signal from kill Signal 15 received: Abnormal termination triggered by abort call Signal 15 received, exiting... 10:24:23 (2924): called boinc_finish(193) Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... Signal 15 received: Software termination signal from kill Signal 15 received: Abnormal termination triggered by abort call Signal 15 received, exiting... SIGSEGV: segmentation violation Stack trace (20 frames): ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu(boinc_catch_signal+0x67)[0x80d4cf7] linux-gate.so.1(__kernel_sigreturn+0x0)[0xf7f1fb70] /lib/i386-linux-gnu/libc.so.6(getenv+0x99)[0xf7a7ba69] /lib/i386-linux-gnu/libc.so.6(+0xaf468)[0xf7afb468] /lib/i386-linux-gnu/libc.so.6(+0xaf835)[0xf7afb835] /lib/i386-linux-gnu/libc.so.6(localtime_r+0x12)[0xf7af9db2] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x80d01b2] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x80d0900] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x80d09f1] linux-gate.so.1(__kernel_sigreturn+0x0)[0xf7f1fb70] linux-gate.so.1(__kernel_vsyscall+0x9)[0xf7f1fb59] /lib/i386-linux-gnu/libc.so.6(nanosleep+0x4b)[0xf7b0b1cb] /lib/i386-linux-gnu/libc.so.6(usleep+0x41)[0xf7b3dbe1] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x80e78a5] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x804fca4] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x80503d7] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x8051b13] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x8051d8b] /lib/i386-linux-gnu/libc.so.6(__libc_start_main+0xf1)[0xf7a64e81] ../../projects/climateprediction.net/hadam4_8.52_i686-pc-linux-gnu[0x804cd21] Exiting... Model crashed: READDUMP: BAD BUFFIN OF DATA tmp/xnnuj.pipe_dummy Model crashed: READDUMP: BAD BUFFIN OF DATA tmp/xnnuj.pipe_dummy Model crashed: READDUMP: BAD BUFFIN OF DATA tmp/xnnuj.pipe_dummy Model crashed: READDUMP: BAD BUFFIN OF DATA tmp/xnnuj.pipe_dummy Model crashed: READDUMP: BAD BUFFIN OF DATA tmp/xnnuj.pipe_dummy Model crashed: READDUMP: BAD BUFFIN OF DATA tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 05:16:20 (2249): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|
©2024 cpdn.org