climateprediction.net home page
Task 22423994

Task 22423994

Name wah2_eas25_n3ru_202012_24_1008_012276146_1
Workunit 12276146
Created 5 Apr 2024, 4:45:43 UTC
Sent 5 Apr 2024, 4:46:04 UTC
Report deadline 14 Jul 2024, 4:46:04 UTC
Received 5 Apr 2024, 10:21:54 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 0 (0x00000000)
Computer ID 1531671
Run time 5 hours 24 min 41 sec
CPU time 5 hours 23 min 58 sec
Validate state Invalid
Credit 0.00
Device peak FLOPS 1.00 GFLOPS
Application version Weather At Home 2 (wah2) (region independent) v8.29
windows_intelx86
Peak working set size 344.27 MB
Peak swap size 310.88 MB
Peak disk usage 0.01 MB
Stderr
<core_client_version>7.16.20</core_client_version>
<![CDATA[
<stderr_txt>
modelGetExecutables: check control files, strTemp0 & 1 : 
C:\ProgramData\BOINC/projects/climateprediction.net/wah2_eas25_n3ru_202012_24_1008_012276146/jobs/xadae.namelists
C:\ProgramData\BOINC/projects/climateprediction.net/wah2_eas25_n3ru_202012_24_1008_012276146/jobs/xacxf.namelists
modelGetExecutables: unzipping control files : strInput & strTmp 
wah2_eas25_n3ru_202012_24_1008_012276146.zip
wah2_eas25_n3ru_202012_24_1008_012276146/jobs
gstrDump[0] = generic_phase1_spinup_eas25_global_aabaka
gstrDump[1] = generic_phase1_spinup_eas25_regional_aabaka
global model: command string: "C:\ProgramData\BOINC/projects/climateprediction.net/wah2am3m2_um_8.29_windows_intelx86.exe" wah2_eas25_n3ru_202012_24_1008_012276146 generic_phase1_spinup_eas25_global_aabaka ic19610315_12_N96 NATclim_ancil_168months_CMIP6-IPSL-CM6A-LR_SST_2009-01-01_2022-12-30_v2403 NATclim_ancil_168months_CMIP6-IPSL-CM6A-LR_SIC_2009-01-01_2022-12-30_v2403 so2dms_prei_N96_1855_0000P oxi.addfa ozone_preind_N96_1879_0000Pv5
regional model: command string: "C:\ProgramData\BOINC/projects/climateprediction.net/wah2rm3m2t_um_8.29_windows_intelx86.exe" wah2_eas25_n3ru_202012_24_1008_012276146
 cpdn_check_running: got RM PID of zero; ignoring this call and waiting for PID via shMem. 
 cpdn_check_running: got RM PID of zero; ignoring this call and waiting for PID via shMem. 
executeModelProcess: MonID=16072, GCM_PID=5048, RCM_PID=18176
12:19:06 (18176): called boinc_finish(193)
Global Worker:: CPDN process is not running, exiting, bRetVal = T, checkPID = 18176, selfPID = 5048, iMonCtr = 2
Controller:: CPDN process is not running, exiting, bRetVal = T, checkPID = 5048, selfPID = 16072, iMonCtr = 1
Model crash detected, will try to restart...
Leaving CPDN_Main::Monitor...
monitor:finished called ... tidying up.
monitor:finished: Uploading out files...
monitor:finished: calling modelResultFiles ...
modelResultFiles : Cleaning up : wah2_eas25_n3ru_202012_24_1008_012276146 in C:\ProgramData\BOINC/projects/climateprediction.net
monitor:finished: Closed output file : stdout_mon.txt
monitor:finished: handing over to boinc_finish(RetVal=0)
12:19:16 (16072): called boinc_finish(0)

</stderr_txt>
<message>
upload failure: <file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_1.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_2.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_3.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_4.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_5.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_6.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_7.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_8.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_9.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_10.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_11.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_12.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_13.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_14.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_15.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_16.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_17.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_18.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_19.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_20.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_21.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_22.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_23.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_24.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
<file_xfer_error>
  <file_name>wah2_eas25_n3ru_202012_24_1008_012276146_1_r1839022604_restart.zip</file_name>
  <error_code>-240 (stat() failed)</error_code>
</file_xfer_error>
</message>
]]>
No trickles!


©2024 cpdn.org